Crest Electronics CDVS-7000 Instrukcja Użytkownika Strona 185

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 341
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 184
User Manual
i Series / iX Series 171
16.5.2.1c
3 Phs Voltage (ac)
97V to 134V, 360Hz
Apply for 5 mins each test
EAWF115_VABN3P360
16.5.2.1c
3 Phs Voltage (ac)
97V to 134V, 800Hz
Apply for 5 mins each test
EAWF115_VABN3P800
16.5.2.2
Momentary Undervoltage (ac)
10V and 60V, 360Hz
Apply for 7 seconds each test
EAWF115_VUND360
16.5.2.2
Momentary Undervoltage (ac)
10V and 60V, 800Hz
Apply for 7 seconds each test
EAWF115_VUND800
16.5.2.3
Abnormal Transients (ac)
16.5.2.3.1 - Abnormal Voltage surge
148V to 180V, 360Hz
Figure 16.5 - apply at 10 sec intervals
EAWF115_AVSUR360
16.5.2.3.1 - Abnormal Voltage surge
148V to 180V, 800Hz
Figure 16.5 - apply at 10 sec intervals
EAWF115_AVSUR800
Przeglądanie stron 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 340 341

Komentarze do niniejszej Instrukcji

Brak uwag