This manual is not intended to elaborate on the intent or purpose of the immunity tests and the
expected behavior of the EUT as described in the MIL-STD-704 documents. It is assumed that
the end-user is familiar with the content of the MIL-STD-704 test standard.
9.8.2.2 Test Coverage
The comprehensiveness of the test that can be performed with the –704 option is determined
primarily by the capabilities of the power source used. Tests that are outside the hardware
capabilities of the power source used will not be enabled and cannot be selected. For these
tests, additional equipment may be required as indicated. The extent of coverage of the –704
option as implemented on the IX Series platform is shown in the table below. Tests marked with
an „x‟ generally require additional hardware to be used. Tests marked „N/A‟ are not applicable to
the corresponding table. Tests marked with a „ ‟ are covered by at least one rev of the MIL-STD-
704.
Load and Current
Harmonic
Measurements
Steady State Limits
for Voltage and
Frequency
Steady State Limits for
Voltage
Voltage Distortion
Spectrum
Normal Voltage
Transients
Voltage Distortion
Spectrum
Abnormal Steady State
Limits for Voltage
Abnormal Voltage
Transients
Normal Voltage
Transients
Emergency Limits for
Voltage
Normal Frequency
Transients
Starting Voltage
Transients
Abnormal Steady
State Limits for
Voltage and Freq.
Abnormal Voltage
Transients
Abnormal Frequency
Transients
Emergency Steady
State Limits for
Voltage and Freq.
1
Note: Some restrictions apply due to voltage range limitations. See section 9.8.2.3 for details.
2
Note: Some restrictions apply due to voltage range limitations. See section 9.8.2.3 for details.