256 i Series / iX Series
9.8.2.5 Initial Setup
The –704 option supports both AC and DC modes of operation. The correct mode is a function of
the EUT to be tested and the operator must select the corresponding operating mode first. This
can be done from the front panel if needed or using the CIGui32 program. Use of the CIGui32
program for all settings will be assumed for the remainder of this chapter.
Seven power groups are covered in the MIL-STD-704 directive:
Single Phase 115VAC / 400 Hz (CF)
Three Phase 115VAC / 400 Hz (CF)
Single Phase 115VAC / Variable Frequency (VF), 360 – 800 Hz.
Three Phase 115VAC / Variable Frequency (VF), 360 – 800Hz.
Single Phase 115VAC / 60 Hz (CF)
The required steady state output settings for each power group must be selected based on the
type of EUT to be tested. These settings can be made from the front panel of the IX Series
power source or from the main CIGui32 control screen.